The output of the transducer is centered around 2.5V with no primary current. With positive primary current, the output will rise to a maximum 4.625V. With negative primary current, the output will fall to 0.375V minimum. These values correspond to the peak measuring range of the transducer. For the positive and negative nominal currents, the output would be 3.125V or 1.875V respectively.
 
                 
                 
                 
 
 
 